FAQ: Choosing the Right Ground Support#

This FAQ explains when to use point supports or a Ground Support base with a fixed footprint, and why the calculated values can differ.

How do I choose the right Ground Support?#

Choose the model that represents the actual connection between the structure and the ground. A point support allows the tower to rotate at its base. A Ground Support base with a 1 × 1 m footprint represents a connection restrained against rotation, as if the tower were bolted to the ground. This difference in support conditions affects the tower's buckling behavior and therefore the calculated support reactions.

As a rule of thumb:

  • Use point supports with fixed truss corners or Box Corners when the structure has more than three legs.
  • Use Ground Support bases with a 1 × 1 m footprint with MPT bases and Sleeve Blocks. These designs require the restraint at the foot shown in the model.
  • For an arch, a Dynamic Base can be connected freely to the tower and attached at different points on the truss.

The actual construction and support settings must match the on-site setup. This rule of thumb does not replace checking the real connection.

Why do calculated values differ between supports?#

The values of 250 kg per foot and up to 550 kg come from two models with different support conditions. They are therefore not directly comparable. In the example considered, which has four legs, the point-support workflow was recommended, provided it represents the actual connection at the foot.

Use the calculated value only for the support arrangement shown in the model. A 1 × 0.5 m base plate must be modeled with its actual dimensions and rotational behavior. Do not automatically treat it as equivalent to a Ground Support base with a 1 × 1 m footprint. Wind speed alone does not determine the required ballast or support reactions.

What must the model represent?#

Before calculating, check that the supports are located at the actual feet and that their restrained directions match the real structure. Also account for the actual footprint, anchoring, and any ballast. For more information about support settings, see Inserting and configuring Ground Support Attachments.